04100011-Abstract

 

Number:

04100011

Download

PDF

Name:

曾憲中

Titles:

教授

Author:

Txer-Ming Jeng, Sheng-Chung Tzeng, Chi-Shan Hsiao, Yu-Chi We

Paper name:

LED之環狀金屬多孔性介質散熱座之自然對流熱傳分析

Name of activity:

2012 綠色科技工程與應用研討會(GTEA)暨綠色能源與冷凍空調學術研討會(GERA)

Keywords:heat transfer, rotating porous cylinder, impinging jet, confined/unconfined conditions, aluminum foams.

Abstract:This work experimentally investigated the heat transfer of a rotating porous cylinder under a circular impinging jet at the confined/unconfined conditions. The dimensions of the Al-foam cylinder were 40mm in diameter (D) and 20 mm height (H) excepting the 4mm-thickness spreader.Air was employed as the coolant . The diameter (d) of the circular nozzle was 20 mm. Relevant parameters included the rotational Reynolds number (Re=788~3163) the jet Reynolds number (Re=3325~16690) and the relative impinging height (C/d=0.05~9) The results indicated that for the pure roatiog condition the average Nusslt number (Nu) of the unconfined system was higher than that of the confined system at C/d=0.05 but there were few differences between these both systems at other at other values of C/d For the pure jet flow condition on the contrary the average Nusslt number (Nu)